EZ-Screen Specs

System Power Requirements Emitter: 24V dc ± 15%, 10% maximum ripple, 100 mA max.
Receiver: 24V dc ± 15%, 10% maximum ripple, 275 mA exclusive of loads.

Response Time 9 to 40 ms depending on number of sensing beams Sensing Range 14 mm resolution models: 0.1 m to 6 m (4" to 20')
30 mm resolution models: 0.1 m to 18 m (4" to 60')

Ambient Light Immunity >10,000 lux at 5° angle of incidence

Emitter Elements Infrared LEDs, 950 nm at peak emission

Status Indicators Emitter:
Red/Green Status Indicator – indicates operating mode (RUN or TEST), Lockout or power OFF condition
7-Segment Display – indicates proper operation, scan code or error code.

Receiver:
Yellow Reset Indicator – indicates whether system is ready for operation or requires a reset
Red/Green Status Indicator – indicates general system and output status
Red/Green Zone Status Indicators – indicates condition (clear or blocked beam) of a defined group of beams 7-Segment Display – indicates proper operation, scan code or error code, total number of beams blocked.

Controls or Adjustments Emitter and Receiver: Scan code switch (selects code 1 or 2).

Receiver (only): Trip/latch output selection switch. EDM (External Device Monitoring) Switch – selects single- or dual-channel monitoring.

EDM Input Signals from external devices can be monitored (single-channel, dual-channel, or no monitoring) via EDM1 and EDM2 terminals in the receiver. Monitored devices must respond within 200 milliseconds of an output change.

Output Configuration
(OSSD1 and OSSD2)
Two OSSD (Output Signal Switching Device) safety outputs:
Solid-state current sourcing outputs for switching 24V dc loads at up to 0.5 A each.
Relay Interface Modules are available for ac or larger dc loads.

Enclosure Size: See "DIMENSION DRAWING" at left
 

Material: Extruded aluminum housing with yellow polyester powder finish; sealed rugged die-cast zinc end caps, acrylic lens cover and polycarbonate access door.

Rating: IEC IP65

Optical Performance This system meets the ±2.5° requirements of IEC 61496-2, section 5.2.9 (type 4)

Operating Conditions Temperature: 0° to +50° C (+32° to 122°F) Max. Relative Humidity: 95% maximum relative humidity (non-condensing)