The components required for suite master are not published. Please check your publish settings in Fusion and republish the site.

"; } else { echo "

An error occured. Please contact the site administrator

Error code: 103

"; } exit(); } require_once($nof_rootDir . "/" . $nof_scriptDir . "/" . "nof_utils.inc.php"); $nof_resources->addFile($nof_langFile); ?> EZ-Screen Muting Spec
Home Vision Motion Controls Sensors Safety Mechanical


Calendar
Testimonies
Linecard
Minority
Contacts
Videos

Vision
Motion
Controls
Sensors
Safety
Mechanical


Sign up for our Email Newsletter

Industrial Control ebay store with new, used, returned, and demo items

Click here for listings for our classes and events

EZ-Screen Muting Spec

System Power Requirements 24V dc ±15% @ 400A max, exclusive of the power needs of the external muting and safety devices.
Supply Protection Circuitry All Inputs and Outputs are protected from short circuit to +24V dc or dc common.
OSSD Outputs Two diverse-redundant solid-state 24V dc, 0.5A sourcing OSSD (Output Signal Switching Device) Safety Outputs. Non-safety Auxilliary Output - PNP solid-state, rated 24v dc @ 250mA.
OSSD Response Time <10 ms
Alternate Power Connections +24V dc ±15% @ 2.5A max, Resettable 2.5A fuse
Status Indication LEDs

SYSTEM STATUS

YELLOW

GREEN

RED

Power Applied (Manual Power-up)

DOUBLE FLASHING

OFF

OFF

Normal Operating Mode

ON

ON

OFF

Lockout Mode

OFF

OFF

FLASHING

Latched Mode

Safety Light Curtain Clear

FLASHING

OFF

OFF

Safety Light Curtain Blocked

ON

OFF

OFF

Override Condition

OFF

ON

ON

Non-Mutable Input is open

OFF

OFF

ON

Diagnostic Code Display Diagnostic Display is a two-digit numeric display that indicates the cause of lockout conditions and the amount of time, in seconds, remaining for the backdoor timer.

Muting Lamp Output A monitored or non-monitored (selectable) sinking output. If monitoring has been selected, the current draw must be within 10 mA to 360 mA.
Maximum Switching Voltage: 30V dc
Maximum Switching Current: 360 mA
Minimum Switching Current: 10 mA

Controls and Adjustments Manual/Auto Power-up
One-Way/Two-Way Muting
Monitored/Non-monitored Mute Lamp Output
One-Channel/Two-Channel/No EDM
Backdoor Timer
Mute On Power-up Enable
Mute Enable Active/Inactive

Inputs 2 Safety Devices – 1 x Mutable and 1 x Non-mutable
2 External Device Monitoring (EDM) – for MPCE or safety device feedback
2 Sets of Muting Devices – for muting logic requirements
1 Mute Enable Input – creates a window of time where muting is permissible
Override – for situations where authorized override is needed
Reset – for re-initiating the module after clearing a Lockout condition
Mounting 4 mounting holes - 5.5 mm (.19")
Enclosure & Environmental Rating Dimensions: 220 mm x 62 mm x 41 mm (8.6" x 2.3" x 1.6")
Rating: NEMA 4, 13, IEC IP65
Connections 1 each, 8-pin minifast® 1 each, 7-pin minifast®
8 each, 5-pin
eurofast® (4-pin if ground connection not used)
Certifications Designed to meet Safety Category 4 per EN954-1. Certifications are in process – coming soon.

 

golfclubs

Calvary CRC Golf

Partner Login

2008 Training Schedule

Cognex DVT , InSight, Checker Training

Click here for listings for our classes and events

Industrial Control Service Inc. --- 9267 Riley St. Zeeland, MI 49464 --- phone: 800-878-6722 --- fax: 616-748-0060